HITACHI INVERTER WJ200-002SF 200-240V 1 PHASE Return Policy Returns accepted within 30 days. Items sold as is cannot be returned, unless description is in error. Buyer pays return freight. Shipping Policy We ship almost all items with 1 business day of cleared payment. We ship USPS and UPS. We can ship on your account. If you will be shipping freight, please be sure to provide all delivery contact information including a phone number. We will need to know if you have a fork lift or dock.
WJ200-022SF 200V 1 PHASE 1-phase input 200V class
Models WJ200- 004SF 007SF 015SF 022SF
Brochure
Applicable motor size kW VT 0.55 1.1 2.2 3
CT 0.4 0.75 1.5 2.2
Quick Reference Guide
HP VT 3/4 1.5 3 4
CT 1/2 1 2 3
Instruction Manual
Rated capacity (kVA) 200V VT 1.2 2 3.3 4.1
CT 1 1.7 2.7 3.8
240V VT 1.4 2.4 3.9 4.9
CT 1.2 2 3.3 4.5
For technical questions specific to your application Call-1-888-476-5944
Input Rating Rated input voltage (V) 1-phase: 200V-15% to 240V +10%, 50/60Hz ±5%
Rated input current (A) VT 7.3 13.8 20.2 24
CT 6.3 11.5 16.8 22
Output Rating Rated output voltage (V) 3-phase: 200 to 240V (proportional to input voltage)
Rated ouput current (A) VT 3.5 6 9.6 12
1 YEAR MANUFACTURERS WARRANTY
CT 3 5 8 11
Minimum value of DB Resistor (O) 100 50 50 35
Cooling method Self-cooling Force Ventilation
Weight kg 1.1 1.6 1.8 1.8 lb 2.4 3.5 4 4
Item General Specifications
Protective housing IP20
Control method Sinusoidal Pulse Width Modulation (PWM) control
Carrier frequency 2kHz to 15kHz (derating required depending on the model)
Output frequency range 0.1 to 400Hz
Frequency accuracy Digital command: ±0.01% of the maximum frequency
Analog command: ±0.2% of the maximum frequency (25°C ±10°C)
Frequency setting resolution Digital: 0.01Hz; Analog: max. frequency/1000
Volt./Freq. characteristic V/f control (constant torque, reduced torque, free-V/F): base freq. 30Hz–400Hz adjustable,
Sensorless vector control, Closed loop control with motor encoder feedback (only V/f control).
Overload capacity Dual rating*6: CT (Heavy duty): 60 sec. @150%
VT (Normal duty): 60 sec. @120%
Acceleration / deceleration time 0.01 to 3600 seconds, linear and S-curve accel/decel, second accel/decel setting available
Starting torque 200% @0.5Hz (sensorless vector control)
DC braking Variable operating frequency, time, and braking force
Freq. setting Operator panel /\ \/ keys / Value settings
External Signal 0 to 10 VDC (input impedance 10kO), 4 to 20mA (input impedance 100O), Potentiometer (1k to 2kO, 2W)
I Via network RS485 ModBus RTU, other network option
N FWD / REV run Operator panel Run/Stop (Forward/Reverse run change by command)
P External Signal Forward run/stop, Reverse run/stop
U Via network RS485 ModBus RTU, other network option
T Intelligent input terminal Terminals 7 terminals, sink/source changeable by a short bar
Functions FW (forward run command), RV (reverse run command), CF1–CF4 (multi-stage speed setting), JG (jog command), DB (external braking), SET (set second
S motor), 2CH (2-stage accel./decel. command), FRS (free run stop command), EXT (external trip), USP (startup function), CS (commercial power switchover),
I SFT (soft lock), AT (analog input selection), RS (reset), PTC (thermistor thermal protection), STA (start), STP (stop), F/R (forward/reverse), PID (PID
G disable), PIDC (PID reset), UP (remote control up function), DWN (remote control down function), UDC (remote control data clear), OPE (operator control),
N SF1–SF7 (multi-stage speed setting; bit operation), OLR (overload restriction), TL (torque limit enable), TRQ1 (torque limit changeover1), TRQ2 (torque
A 68 functions assignable limit changeover2), BOK (Braking confirmation), LAC (LAD cancellation), PCLR (position deviation clear), ADD (add frequency enable), F-TM (force terminal
L mode), ATR (permission of torque command input), KHC (Cumulative power clear), MI1–MI7 (general purpose inputs for EzSQ), AHD (analog command hold),
CP1–CP3 (multistage-position switches), ORL (limit signal of zero-return), ORG (trigger signal of zero-return), SPD (speed/position changeover), GS1,GS2 (STO
inputs, safety related signals), 485 (Starting communication signal), PRG (executing EzSQ program), HLD (retain output frequency), ROK (permission of run
command), EB (rotation direction detection of B-phase), DISP (display limitation), NO (no function)
O Intelligent output terminal Functions RUN (run signal), FA1–FA5 (frequency arrival signal), OL,OL2 (overload advance notice signal), OD (PID deviation error signal), AL (alarm signal),
U OTQ (over/under torque threshold), UV (under-voltage), TRQ (torque limit signal), RNT (run time expired), ONT (power ON time expired), THM (thermal
T warning), BRK (brake release), BER (brake error), ZS (0Hz detection), DSE (speed deviation excessive), POK (positioning completion), ODc (analog
P voltage input disconnection), OIDc (analog current input disconnection), FBV (PID second stage output), NDc (network disconnect detection), LOG1–
U 48 functions assignable LOG3 (Logic output signals), WAC (capacitor life warning), WAF (cooling fan warning), FR (starting contact), OHF (heat sink overheat warning), LOC
T (Low load), MO1–MO3 (general outputs for EzSQ), IRDY (inverter ready), FWR (forward operation), RVR (reverse operation), MJA (major failure),
WCO (window comparator O), WCOI (window comparator OI), FREF (frequency command source), REF (run command source), SETM (second motor in
S operation), EDM (STO (safe torque off) performance monitor), OP (option control signal), NO (no function)
I Monitor output (analog) Output freq., output current, output torque, output voltage, input power, thermal load ratio, LAD freq., heat sink temperature, general output (EzSQ)
G Pulse train output [PWM output]
N Output freq., output current, output torque, output voltage, input power, thermal load ratio, LAD freq., heat sink temperature, general output (EzSQ)
A (0-10VDC, 32kHz max.) [Pulse train output]
L Output frequency, output current, pulse train input monitor
Alarm output contact ON for inverter alarm (1c contacts, both normally open or closed available.)
Other functions Free-V/f, manual/automatic torque boost, output voltage gain adjustment, AVR function, reduced voltage start, motor data selection, auto-
tuning, motor stabilization control, reverse running protection, simple position control, simple torque control, torque limiting, automatic carrier
frequency reduction, energy saving operation, PID function, non-stop operation at instantaneous power failure, brake control, DC injection
braking, dynamic braking (BRD), frequency upper and lower limiters, jump frequencies, curve accel and decel (S, U, inversed U,EL-S), 16-stage
speed profile, fine adjustment of start frequency, accel and decel stop, process jogging, frequency calculation, frequency addition, 2-stage
accel/decel, stop mode selection, start/end freq., analog input filter, window comparators, input terminal response time, output signal delay/
hold function, rotation direction restriction, stop key selection, software lock, safe stop function, scaling function, display restriction, password
function, user parameter, initialization, initial display selection, cooling fan control, warning, trip retry, frequency pull-in restart, frequency
matching, overload restriction, over current restriction, DC bus voltage AVR
Protective function Over-current, over-voltage, under-voltage, overload, brake resistor overload, CPU error, memory error, external trip, USP error, ground fault detection
at power on, temperature error, internal communication error, driver error, thermistor error, brake error, safe stop, overload at low speed, modbus
communication error, option error, encoder disconnection, speed excessive, EzSQ command error, EzSQ nesting error, EzSQ execution error, EzSQ user trip
Operating enviroment Temperature Operating (ambient): -10 to 50°C / Storage: -20 to 65°C
Humidity 20 to 90% humidity (non-condensing)
Vibration 5.9m/s2 (0.6G), 10 to 55 Hz
Location Altitude 1,000m or less, indoors (no corrosive gasses or dust)
Coating color Black
Options Remote operator unit, cables for the units, braking unit, braking resistor, AC reactor, DC reactor, EMC filter---- NEW SURPLUS-- OPENED FACTORY BOX--12/18/TC
SS183-- 1608B---GW 057004---5.40#
ALL ITEMS SOLD/SHIPPED OUTSIDE OF NORTH AMERICA ARE SOLD AS/IS WITH NO WARRANTIES, NO RETURNS AND NO REFUNDS. ALL ITEMS SOLD/SHIPPED WITH IN NORTH AMERICA HAVE A 30 DAY RETURN POLICY